IR Spectroscopy for Protein Quantitation

By | June 6 2012

Problem: Classical methods for protein quantitation rely on colorimetric assays, such as those involving protein-copper chelation (bicinchoninic acid (BCA) and Lowry assays) and dye-binding based detection (Bradford and “660 Assay”) or ultraviolet (UV) spectroscopy. Each of these methods has limitations. In colorimetric assays, standard curve determinations differ considerably from assay to assay, affecting reproducibility of protein concentration estimations1. Similarly, the UV spectroscopy-based method relies on absorbance at 280 nm by a protein’s aromatic amino acids, predominantly tryptophan and tyrosine. Therefore, those proteins, such as Protein A, that do not contain aromatic amino acids, cannot be quantified based on 280 nm absorbance. Amino acid analysis delivers possibly the most accurate protein quantitation; however, it is expensive and slow if samples are sent to a third party for analysis. If amino acid analysis is performed in-house, it requires time-consuming sample manipulation and specialized equipment. In all of these methods, sensitivity to buffer components and contaminating biomolecules can often render the assay unreliable2.

 

Solution: The Direct Detect™ system (EMD Millipore), an infrared (IR)-based spectrometry system, represents an innovation in biomolecular quantitation. The key to this advance lies in a new membrane technology for preparing and presenting aqueous biological samples to make them compatible with infrared analysis. It employs a hydrophilic polytetrafluoroethylene (PTFE) membrane that is designed to be transparent in most of the infrared spectral region and enables application of biomolecule solutions directly onto the membrane. The system has been optimized for detection and quantitation of proteins. By measuring amide bonds in protein chains, the system accurately determines an intrinsic component of every protein without relying on amino acid composition, dye binding properties or redox potential.

IR-based protein quantitation using the Direct Detect™ system involves measuring the intensity of the Amide I signal in the protein’s IR spectrum, and subtracting the signal contributed by buffer alone in that region. A sample spectrum (Figure 1) shows that the IR spectrum of SDS does not have a strong signal in the Amide I region that would significantly interfere with protein quantitation. As a result, IR-based quantitation retains accuracy and reproducibility in the presence of SDS. Similarly, the IR spectra of reducing agents such as DTT do not interfere with Amide I quantitation (spectra not shown). Also, IR-based quantitation of proteins is independent of time. Unlike colorimetric Bradford and micro BCA assays, which are based on indirect detection of a secondary reaction and whose signals continue to change over time, the IR signal of a protein is not affected by the time between sample preparation and data acquisition.

The stability of the IR signal over time, together with compatibility with detergents and reducing agents, make IR-based quantitation a more convenient, flexible, universal approach to measuring protein levels in complex mixtures, compared to the Bradford and BCA colorimetric assays. Also because assay-free, IR-based quantitation only requires a standard curve to be generated once (instead of for every experiment), quantitating single samples using the Direct Detect™ system is faster than quantitating single samples using colorimetric assays. Benchmarking every experiment to the same, robust standard curve also provides more reproducible results and facilitates intra-assay comparisons across multiple experiments referencing the same standard curve.

For more information on the Direct Detect™ system, please visit http://www.millipore.com/directdetect

The characteristic peaks of the SDS IR spectrum are distinct from the Amide I region of the protein spectrum.

Sources

1. Manneberg, M., et al. (1992). Comparison of the Coomassie brilliant blue, bicinchoninic acid and Lowry quantitation assays, using non glycosylated and glycosylated proteins. J. Biochem Biophys Methods., Jun; 24(3-4):265-74

2. Kessler, R.J., Fanestil, D.D. (1986). Interference by Lipids in the Determination of Protein Using Bicinchoninic Acid. Analytical Biochemistry, 159:138-142.

Categories

How It Works and How It Works
Advertisement
ELGA
ELGA
Get Help with Your Lab Equipment
…or help others.

Build your Lab Bench and get notifications and updates for the lab equipment you own!

www.labwrench.com
  • Facebook
  • LinkedIn
  • Twitter
  • Vimeo
  • RSS
Now Available in the App Store!

Related Articles

Advertisement
W.S. Tyler
W.S. Tyler

Subscribe to the Magazine

Click Here for your free subscription to Lab Manager Magazine®

E Newsletters

Click Here to subscribe to any of the following Lab Manager Magazine® E Newsletters

  • Lab Manager Magazine Weekly Monitor
  • New Product Alerts
  • eAnalytical Monthly
  • eLifeScience Monthly
  • eLab Equipment Monthly
  • Product Surveys and Event Promotions
  • Events and Webinars
Sign Up for Newsletters

Lab Video

Advertisement
See All Lab Videos

Webinars & Events

See All Webinars & Events
  • Facebook
  • LinkedIn
  • Twitter
  • Vimeo
  • RSS
Now Available in the App Store!

Page Generated: May 21 2013

Advertisement