Tracking the Aluminum Used to Purify Tap Water

In order to provide clear, safe tap water it is necessary to remove particles called colloids from raw water

by Kobe University
Register for free to listen to this article
Listen with Speechify
0:00
5:00

Analysis using 27Al qNMR (quantitative NMR) spectroscopyFig 1. Analysis using 27Al qNMR (quantitative NMR) spectroscopy. Each spectrum can be measured in just three minutes.Image courtesy of Kobe University

A Kobe University research group including Associate Professor Maki Hideshi (Center for Environmental Management), PhD candidate Sakata Genki (Graduate School of Engineering, Department of Chemical Science and Engineering, currently employed at Central Glass Co., Ltd.) and Professor Mizuhata Minoru (Graduate School of Engineering) have developed a new analysis method that uses magnetic fields to quickly and accurately measure the concentration of aluminum used to purify tap water. These findings can potentially be used in developing efficient and environmentally-conscious coagulants for water treatment. The findings were presented on May 29, 2016 at the 76th Japan Society for Analytical Chemistry Symposium.

Related Article: Contaminated Environmental Samples: New Methods to Extract and Analyze

In order to provide clear, safe tap water it is necessary to remove particles called colloids from raw water. These particles are very small, between nanometer order and micrometer order in diameter. Polychlorinated aluminum is used as a coagulant in the water treatment process to collect and dispose of these particles. However, aluminum ions can be toxic for fish and inhibit plant growth. The Japanese Water Works Law specifies that aluminum concentration in water must be limited to below 0.1ppm (1:10,000,000).

Get training in Chemical Hygiene and earn CEUs.One of over 25 IACET-accredited courses in the Academy.
Chemical Hygiene Course

Various hydrolyzed species of aluminum ion can be detected in water. Until now the “ferron method,” involving pigments and absorption meters, has been widely used to calculate the concentration of these compounds. However, this method has some disadvantages: the analysis takes several hours and the results often contain errors.

hydrolysis reaction of aluminum ionsFig 2. The hydrolysis reaction of aluminum ions. Measurements can be taken a few minutes after the solution is prepared. The measurement process is non-destructive, meaning that the same solution can be monitored over a long period.Image courtesy of Kobe UniversityAssociate professor Maki’s research group optimized NMR equipment to develop an analysis method called “27 Al qNMR (quantitative NMR) spectroscopy” that accurately measures the abundance of each aluminum compound. Notably, measurements using this analysis method can be carried out in just three minutes, and the concentration of hydrolyzed species can be calculated to within a very small margin of error in all pH ranges.

After the agglomeration mechanism of sludge including the aluminum ion was analyzed, the group discovered that when there is a high concentration of aluminum ions, after roughly 100 minutes a Keggin-type tridecameric cluster (K-Al13 ) is formed, and after a few months polymerization occurs.

As well as making it easier to measure the concentration of aluminum ions in water, this new analysis method has also clarified the structural changes aluminum ions undergo over time. These findings could potentially contribute to the development of high-performance, environmentally-conscious coagulants that can act more efficiently on colloids.