Key takeaways
- A chemical storage compatibility chart shows which hazard groups can be stored together and which must be separated because they could react dangerously if mixed.
- Many charts online are material compatibility charts, which show whether a chemical damages plastics, elastomers, or metals; that’s a different question.
- Broad rules cover most labs: keep acids from bases, oxidizers from flammables and organics, water-reactives from aqueous materials, and cyanides and sulfides from acids.
- The EPA’s 1980 compatibility chart and NOAA’s CAMEO Chemicals reactivity tool predict hazards from mixing reactive groups; SDS Sections 7 and 10 give chemical-specific storage and incompatibility information.
- Charts are guides, not guarantees. Check the SDS, consider chemicals with multiple hazards, and involve EHS for unusual materials.
Type “chemical compatibility chart” into a search engine and most of the top results answer a question about materials: will this solvent soften polypropylene, swell a Viton seal, or attack a PVC pipe? Those charts are useful, but they won’t tell you whether two bottles on the same shelf could start a fire if they broke.
A chemical compatibility chart for storage does that. It groups chemicals by how they react and shows which groups can share a cabinet and which must be kept apart. This article provides a simplified storage compatibility chart, explains the main reference tools behind it, and covers how to check specific chemicals and choose compatible containers. For the wider storage picture, see our guide to segregating chemicals by hazard class.
What is a chemical compatibility chart?
| Storage (reactivity) compatibility | Material compatibility | |
|---|---|---|
Question it answers | Will these chemicals react dangerously if they mix? | Will this chemical damage this container, tubing, or seal material? |
Typical format | Hazard or reactive groups against each other, with expected reactions | Chemicals against materials, rated for resistance |
Used for | Storage segregation, waste consolidation, spill planning | Choosing containers, secondary containment, tubing, and equipment |
Main references | SDS, EPA compatibility chart, NOAA CAMEO Chemicals | Manufacturer resistance data for specific materials |
Most labs need both: a reactivity chart to decide what goes where, and material data to make sure containers and containment trays can hold what’s in them.
Which chemical groups can be stored together?
The simplified chart below summarizes common storage rules used in university and industry chemical hygiene programs. “No” means store in different cabinets or, at minimum, separate secondary containment. Always confirm against the SDS and your institution’s rules.
| Group | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
|---|---|---|---|---|---|---|---|---|
1. Flammables | Yes | No | No | No | Check | No | No | Check |
2. Oxidizers | No | Yes | Check | Check | No | Check | No | No |
3. Inorganic acids | No | Check | Yes | Check | Check | No | No | No |
4. Oxidizing acids | No | Check | Check | Yes | No | No | No | No |
5. Organic acids | Check | No | Check | No | Yes | No | No | No |
6. Bases | No | Check | No | No | No | Yes | No | Check |
7. Water-reactives | No | No | No | No | No | No | Yes* | No |
8. Cyanides/sulfides | Check | No | No | No | No | Check | No | Yes |
Columns 1–8 follow the numbered row groups. Yes = generally compatible; Check = compatible in some cases, confirm with the SDS; No = store apart. *Water-reactives also need protection from moisture and from each other where reactivities differ.
A few pairings deserve emphasis. UC Berkeley’s guidance notes that nitric and perchloric acids are incompatible with organic acids such as acetic acid, so oxidizing acids need separation even within the acid family. Cyanide and sulfide salts release toxic gases with acids. Oxidizers and flammables together feed fires. And many chemicals belong to more than one group: UW–Madison’s storage guide explains how to prioritize, for example storing a pyrophoric flammable by its pyrophoric hazard.
How do you read the EPA compatibility chart?
The most widely reproduced reactivity chart comes from a 1980 EPA report, A Method for Determining the Compatibility of Hazardous Wastes, which classifies materials into 41 reactivity groups. As reproduced by Rutgers, each cell where two groups meet shows the expected consequences of mixing, using codes such as:
| Code | Meaning |
|---|---|
H | Heat generation |
F | Fire |
G | Innocuous, non-flammable gas generation |
GT | Toxic gas formation |
GF | Flammable gas formation |
E | Explosion |
P | Violent polymerization |
S | Solubilization of toxic substance |
U | May be hazardous, but unknown |
The chart was designed for hazardous waste, and its own note is a useful warning for anyone using it for storage: as the University of Wisconsin System’s copy states, it’s an indication of some hazards on mixing, and because of the differing activities of thousands of compounds, no chart can be definitive or all-inclusive.
How do you check a specific chemical?
- Start with the SDS. Section 7 (handling and storage) gives storage conditions, and Section 10 (stability and reactivity) lists incompatible materials. As Los Angeles County’s hazardous materials guidance puts it, the SDS is the best way to determine incompatibility.
- Use NOAA’s CAMEO Chemicals. Its reactivity tool assigns each chemical to one or more of 68 reactive groups and predicts hazards when you mix chemicals in a virtual mixture.
- Consider every hazard class. A chemical that is both corrosive and flammable must satisfy both sets of rules, or the higher-priority hazard as defined by your EHS program.
- Check special cases. Peroxide formers, pyrophorics, and highly toxic materials have their own requirements; see Chemical Shelf Life and Expiration Management: Peroxide Formers, Dating, and Disposal.
- Ask EHS for anything unusual, including research chemicals without complete SDS data.
What about container and containment materials?
Storage compatibility depends on the container too. Secondary containment trays need to resist what they might catch; the University of Maryland recommends HDPE as the most chemical-resistant plastic for containment, as its EHS FAQ notes, while Oregon State University’s guidelines suggest polyethylene or stainless steel trays to physically separate incompatibles. For specific container, tubing, or seal choices, consult manufacturer material resistance data for the exact chemical, concentration, and temperature. Flammables that need refrigeration also need the right unit; see our guide to flammable-safe refrigerators.
Where compatibility charts fall short
- Concentration and quantity matter. Dilute solutions and small quantities behave differently from concentrated stock.
- Mixtures and waste are less predictable. Waste containers combine many chemicals, which is why the EPA chart was built for waste in the first place.
- Charts generalize. Exceptions exist within every group.
- Fire codes add limits. Compatibility doesn’t address how much of each hazard class you can store; see NFPA 45 for Labs: Fire Code Quantity Limits, Control Areas, and Storage Rules.
A compatibility checklist for lab storage
- Storage groups are defined and labeled. Labeling cabinets and shelves by storage group makes the chart usable day to day. A simple color code helps.
- Every chemical is assigned to a group before shelving. Assign groups at receipt using the SDS, and record them in the inventory so placement is consistent.
- Multi-hazard chemicals follow priority rules. Document which hazard takes priority for storage, and add secondary containment where a chemical straddles groups.
- Oxidizing acids and cyanides get special attention. These are common sources of dangerous pairings. Separate them explicitly, even within broader acid or toxic groups.
- SDS Section 10 is checked for exceptions. Charts generalize; the SDS lists specific incompatibilities that may not fit the broad groups.
- Containment materials match their contents. Use HDPE, polypropylene, or stainless trays as appropriate, and check manufacturer resistance data for unusual chemicals.
- Waste containers follow compatibility rules too. Mixing incompatible wastes is a leading source of lab incidents. Apply the same chart, or the EPA method, to waste streams.
- The chart is reviewed when new chemical classes arrive. New research directions bring new hazards. Update groups and placement when the inventory changes.
A compatibility chart is only useful if it changes where bottles go. Define your storage groups, check the SDS for exceptions, choose containers that can hold what they’re given, and revisit the chart whenever the chemistry changes.
This article was produced under Lab Manager’s AI Editorial Guidelines