How to Tell Whether Your Lab’s Quality Management System is Working

A closer look at daily work can reveal whether your lab’s quality management system supports lasting improvements—and where it needs attention

Written byLauren Everett
| 4 min read
Two lab leaders evaluating elements of quality management system
Register for free to listen to this article
Listen with Speechify
0:00
4:00

A corrective action is closed, the training record is complete, and the revised procedure has been approved. Before moving on, ask someone at the bench to show you what changed.

Can they find the new instructions? Do they understand when to stop work? Does the revised process address the problem that prompted the change?

Evaluating a laboratory’s quality management system (QMS) means connecting its records to what happens during the workday. Managers need evidence that the system helps staff recognize problems, respond to them, and sustain improvements. Start with a few targeted checks, then use the findings to decide where a broader review is needed.

Follow the work through an audit

Choose a recent sample or project and trace it from receipt through reporting. Compare the records with the applicable procedures, then speak with the people who performed the work. Include handoffs between teams, where responsibility for the next step may need clarification.

Ask staff to demonstrate how they handle an exception. If sample information is incomplete, for example, who decides whether work can proceed, and where is that decision recorded? Compare their explanation with the procedure and a recent example.

Use internal audits to examine these connections. ISO 19011 provides a framework for planning and conducting management system audits, including evaluating the competence of the people performing them.

Digital audit tools can help capture evidence and assign follow-up actions. Evaluate whether their checklists prompt reviewers to examine practice or encourage yes-or-no answers about whether documents exist. Retain space for observations that fall outside the checklist.

Check what happened after corrective action

Review corrective and preventive action (CAPA) records alongside recurring deviations. Group events by the affected process, not just their assigned category. A sample identification problem and a reporting correction may warrant examination of the same handoff.

For selected actions, identify what evidence supported closure. Was a procedure revised, or did someone also check whether the change worked? Look for effectiveness criteria tied to the original problem and a follow-up period appropriate to how often the activity occurs.

For example, after changing a sample labeling process, review subsequent work for the same failure and observe how staff apply the new instructions. If it recurs, examine whether the investigation missed a contributing condition before repeating the intervention.

Read trends in context. Compare deviations with workload and changes in reporting practices. Ask whether fewer reports reflect fewer problems or difficulty reporting them. Pair counts with evidence from audits and staff discussions.

Test document control at the point of use

Select a recently revised standard operating procedure (SOP). Ask an employee to retrieve the version they would use during a routine task. Check the bench copy, linked forms, and any local files against the approved version.

Then trace the revision forward. Were affected staff notified before implementation? Were related instructions updated? Could someone still access an obsolete copy and mistake it for the current one? WHO’s laboratory quality document guidance emphasizes current versions at the point of use and removing obsolete documents from circulation.

Electronic document control can support approvals and version tracking. Test those functions with a realistic revision, including what happens when an approver is absent. Check whether staff can reach instructions where they work, rather than relying on someone else to retrieve them.

Lab manager academy logo

Lab Quality Management Certificate

The Lab Quality Management certificate is more than training—it’s a professional advantage.

Gain critical skills and IACET-approved CEUs that make a measurable difference.

Observe whether training carries into practice

A completed assignment records participation. To evaluate training effectiveness, ask employees to demonstrate the task and explain decisions that require judgment.

Use an observation, review of completed work, or a scenario matched to the employee’s role. WHO’s personnel guidance identifies several approaches to competency assessment, including direct observation, record review, and problem-solving exercises.

If practice differs from the SOP, ask what makes the documented approach difficult. Examine access to equipment and competing workload expectations before deciding that more training is the appropriate response.

Include experienced staff and different shifts. Ask which steps people adapt when work backs up and how they raise concerns. Use those conversations to investigate staff adherence and whether supervisors reinforce the same expectations.

Make management review produce decisions

Select an issue discussed at the last management review and follow it forward. Identify the decision, the responsible person, and the resources committed. Then check what happened.

If the same unresolved item returns at each meeting, determine what blocks progress. Does the owner lack authority? Has the team agreed on what successful completion would look like?

Interested in lab leadership?

Register for a FREE Lab Manager account to subscribe to our Lab Leadership Digest Newsletter.
Subscribe for Free

Bring the evidence together. A training backlog, recurring deviation, and overdue SOP revision may warrant a shared discussion about capacity. Record the decision and how management will evaluate its effect. At the next review, examine that outcome alongside the action’s completion status.

Ask tools and vendors to prove their fit

Use the weaknesses identified in the review to define what support the lab needs. If duplicate entry consumes staff time, require a demonstration of how information moves between the QMS and existing laboratory systems. Establish which system owns each record and how failed transfers become visible.

Ask vendors to demonstrate a workflow using representative, nonconfidential lab information. Follow a deviation through investigation, approval, and effectiveness review. Have routine users complete the steps and note where they need help.

For dashboards, choose measures linked to decisions: overdue high-risk actions, repeat findings, or time awaiting approval. Confirm definitions, refresh timing, and whether users can inspect the underlying records before relying on a summary.

Evaluate ongoing support as part of the purchase. Clarify responsibility for configuration, updates, and troubleshooting. Ask about response commitments, staff training, data export, and support for any required validation. Request references from labs with comparable workflows.

Before expanding a tool or service, pilot it in one process. Compare administrative effort, duplicate entry, and missed follow-ups with a baseline. Include the time needed to maintain it. Use that evidence to judge whether the support helps staff keep the QMS working or creates another system they must work around.

Frequently Asked Questions (FAQs)

  • What steps should I take to conduct an internal audit of a laboratory's quality management system?

    Choose a recent project, trace it from receipt through reporting, compare records and procedures, and speak with the staff involved. Internal audits should also address handoffs, staff understanding of procedures, and decision-making processes.

  • What should I do if recurring issues are noted in a management review?

    If the same unresolved issue appears in each management review, identify potential blockers such as a lack of authority for responsible individuals or unclear success criteria. Gather evidence such as training backlogs and overdue SOP revisions for shared discussion.

  • How do I ensure document control is effective in a quality management system?

    To test document control, select a revised standard operating procedure (SOP), verify access to the current version, ensure all staff are notified of updates, and remove obsolete documents from circulation to prevent confusion.

Add Lab Manager as a preferred source on Google

Add Lab Manager as a preferred Google source to see more of our trusted coverage.

About the Author

  • Lauren Everett headshot

    Lauren Everett is the managing editor for Lab Manager. She holds a bachelor's degree in journalism from SUNY New Paltz and has more than a decade of experience in news reporting, feature writing, and editing. She oversees the production of Lab Manager’s editorial print and online content, collaborates with industry experts for speaking engagements, and works with internal and freelance writers to deliver high-quality content. She has also led the editorial team to win Tabbie Awards in 2022, 2023, 2024, and 2026. This awards program recognizes exceptional B2B journalism and publications. 

    Lauren enjoys spending her spare time hiking, snowboarding, and keeping up with her two young children. She can be reached at leverett@labmanager.com.

    View Full Profile

Related Topics

Loading Next Article...
Loading Next Article...
Current Magazine Issue Background Image

CURRENT ISSUE - October 2026

Why Lab Teams Resist Change—And How Leaders Can Respond

Addressing the human side of automation, AI, and operational change

October 2026 Lab Manager Cover Image