Shimadzu Scientific Instruments has launched the MultiNA II MCE-301 Microchip Electrophoresis System, a benchtop automated electrophoresis platform for DNA and RNA size analysis across next-generation sequencing (NGS), genome editing, and RNA-based therapeutic workflows. It replaces manual gel electrophoresis, consolidating RNA integrity scoring, NGS library quality control (QC), and mutation screening into a single instrument that runs unattended once loaded.
Editor's Note: Nucleic acid QC instrumentation faces growing pressure from three converging demand drivers: expansion of CRISPR-based screening programs, the surge in mRNA therapeutic development requiring integrity-verified starting material, and the scaling of NGS core facilities processing libraries daily. Procurement teams evaluating this category now face a tighter decision window as upgrade cycles align with FY2027 budget planning. This announcement provides a concrete basis for specification comparison before year-end commitments close.
Automated microchip electrophoresis: what it replaces
Automated microchip electrophoresis replaces a manual gel-based protocol that typically requires more than two hours of setup, separation, staining, and visual band interpretation; the MultiNA II performs all of these steps automatically. Contamination risks, gel-to-gel variability, and subjective visual scoring introduce error at critical quality gates; labs weighing the automation tradeoffs in genomics workflows increasingly require both quantitative output and fewer manual steps per sample.

The MultiNA II MCE-301 accepts up to 96 samples in a removable rack and two reagent kit types in a single tray load, starting analysis in 10 minutes.
Shimadzu
The MultiNA II uses a quartz microchip substrate with integrated separation channels and electrodes, completing every step from sample dispensing through chip rinsing in 10 minutes of preparation time. It accommodates up to 96 samples in a removable rack and accepts two reagent kit types in a single tray load. Pausing an active run to add up to 120 samples accommodates multi-user scheduling in shared-access labs.
Does one platform cover RNA, NGS, and genome editing QC?
The MultiNA II MCE-301 addresses all three through automated electrophoresis in a single run, calculating RNA integrity, qualifying NGS libraries, and screening genome edits without instrument switching.
Its RNA Integrity Index (RII) function scores total RNA quality immediately after extraction, the point at which RNA is most vulnerable to degradation. Labs use these scores to decide whether samples meet the threshold for RNA sequencing, in vitro transcription, or mRNA therapeutic manufacturing. RII values show a coefficient of determination (r²) of 0.95 or higher against established microchip electrophoresis platforms, supporting cross-platform comparability in mixed instrument environments.
The MultiNA II covers four QC workflow areas; the table maps each to its analytical function and primary output.
| Workflow area | Primary analytical function | Key output |
|---|---|---|
| RNA quality control | RNA Integrity Index (RII) calculation | Integrity score; r² ≥ 0.95 vs. established platforms |
| NGS library QC | Smear analysis; size and concentration measurement | Average fragment size; library concentration to 5 pg/µL (high-sensitivity kit) |
| Genome editing | Heteroduplex mobility assay (HMA); grouping and molar ratio analysis | Automatic homo/hetero discrimination; quantitative mutation score from HMA, Cel-I assay, or polymerase chain reaction (PCR)-RFLP data |
| mRNA therapeutics / LNP | mRNA purity analysis; integrity in encapsulated and purified material | Purity ratio detection across concentration ranges |
Using differential electrophoretic mobility, HMA identifies mutation-containing samples and assigns them to homo or hetero genotype groups automatically, replacing subjective visual interpretation. A positive control drives the DNA fingerprinting function, grouping results by sample type and supporting labs scaling QC in CRISPR workflows from discovery into higher-throughput screening.
High-sensitivity detection: the DNA-HS12000 Kit
Paired with smear analysis, the DNA-HS12000 Kit extends the MultiNA II's detection range to concentrations as low as 5 pg/µL for NGS library evaluation. Under-concentrated libraries often pass visual inspection yet fail sequencing runs, generating reagent waste and scheduling delays. Reliable NGS pipelines depend on upstream QC to catch those failures before samples enter the sequencer.
Four operational features extend the instrument's practical value across space-constrained, data-heavy, and sustainability-focused labs:
- Automated sample dilution: The system dilutes up to 48 samples with purified water at 5×, 10×, or 20-fold factors; users must supply separate tubes to collect the diluted output.
- Data continuity: Gel image and electropherogram data from the predecessor MCE-202 MultiNA imports directly into the new software, so historical runs can be reviewed alongside current data.
- Energy and water reduction: The MultiNA II consumes 30% less power and 25% less purified water for rinsing than the prior model, supporting lab energy and water reduction commitments without compromising throughput.
- Physical footprint: At 15% smaller in floor area and 27% shorter in height (front door open), the system fits benches where taller, wider predecessors could not.
The MultiNA II also integrates with Shimadzu's Centrifugal Field-Flow Fractionation (CF3) system for lipid nanoparticle (LNP) and adeno-associated virus (AAV) characterization. After CF3 sizes LNP or AAV vectors, extracted mRNA or single-strand DNA runs on the MultiNA II for confirmation, providing sequential verification of both delivery vehicle and nucleic acid cargo. This path maps to requirements set out in the FDA gene therapy CMC guidance and WHO mRNA vaccine quality standards.
Multi-workflow QC on a single benchtop instrument
The MultiNA II MCE-301 replaces separate manual electrophoresis protocols for RNA integrity, NGS library QC, and genome editing mutation screening with one automated system, reducing hands-on time and genomics instrument cost and complexity. Power consumption drops 30%, rinsing water use falls 25%, and a 15% smaller bench footprint makes it viable in labs where space and sustainability targets constrain instrument selection. As mRNA therapeutics and large-scale NGS drive demand for nucleic acid QC across pharma, biotech, and academic genomics, automated electrophoresis platforms that span multiple workflow types from a single benchtop are becoming standard infrastructure rather than optional upgrades.