Quantera Analytical has launched the Curio HS, a parallel, cartridge-based headspace analysis platform that lets food, beverage, fragrance, and environmental labs prepare dozens of samples at once instead of one at a time. Interchangeable sorbent cartridges seat over a standard-footprint multi-well plate; the loaded array then feeds directly into gas chromatography-mass spectrometry (GC-MS), gas chromatography with flame ionization detection (GC-FID), or chromatography-free mass spectrometers.
Editor's Note: The early-access program offers complimentary method development, which lowers validation costs before a purchase commitment. For procurement teams weighing whether to refresh extraction workflows now or wait, the platform's instrument compatibility with existing GC-MS assets, rather than requiring new capital, changes the financial calculus for labs already equipped. The co-validation work underway with the USDA Agricultural Research Service also provides a credible third-party data trail for labs that require independent method support before adoption.
Headspace analysis: parallel extraction, any sorbent, any instrument
The Curio HS processes multiple samples simultaneously, supports any sorbent cartridge chemistry, and is compatible with instruments most labs already own: three capabilities single-fiber extraction cannot combine. Standard solid-phase microextraction (SPME) fiber technology processes one sample at a time, restricts sorbent selection to a narrow set of coatings, and requires analytes to desorb directly into a GC system. That sequential design ties headspace analysis capacity to instrument time rather than sample volume, creating queues at harvest and making point-of-collection sampling impractical.

The Curio HS plate holds one sorbent cartridge per well; swapping cartridge chemistry requires no change to the manifold or workflow.
Quantera Analytical
The extraction geometry traces to Professor Gavin Sacks's laboratory at Cornell University, where Quantera describes twelve peer-reviewed publications as its foundation; Quantera holds an exclusive Cornell patent license and has filed additional applications on the cartridge design. Liquid or solid samples load into a rugged multiwell plate, and a sorbent cartridge seals above each well in under two minutes per sample. Because each cartridge is a discrete, self-contained unit, labs switch between conventional polymers and advanced sorbent chemistries simply by swapping cartridges, with no change to hardware or workflow.
Nine workflow dimensions show where the Curio HS diverges from one-at-a-time extraction, with the largest gaps on throughput, per-sample cost, and sorbent flexibility:
| Workflow dimension | Curio HS | Fiber-based extraction |
|---|---|---|
| Extraction format | Parallel (multiwell plate, 24 samples) | Sequential (one sample per fiber) |
| Prep time per sample | Under 2 minutes | 15–60 minutes (fiber equilibration) |
| Throughput vs. DART-MS | Up to 60x increase | Baseline (1×) |
| Per-sample cost vs. DART-MS | Up to 80% reduction | Baseline |
| Per-sample cost vs. GC-MS | ~50% reduction | Baseline |
| Sorbent options | Conventional polymers + advanced chemistries | Limited to available fiber coatings |
| Field/point-of-collection use | Yes: cartridges shipped, not raw material | Rarely practical |
| Instrument compatibility | GC-MS, GC-FID, DART-MS (LC workflows in development) | Primarily GC-MS |
| Method transfer from existing SPME methods | Minimal re-optimization required | Not applicable |
Curio HS validation: Gallo, USDA, and contract labs
Quantera has secured validation partnerships across three sectors: a pilot with E. & J. Gallo Winery at its Modesto, California facility, a co-authored validation study with the USDA Agricultural Research Service, and a high-throughput workflow collaboration with a major wine contract laboratory. "The Curio HS eliminates the sample preparation bottleneck that has limited what you can test for and what tool you can measure it on," said Terry Bates, PhD, founder and CEO of Quantera. "It's a dramatic expansion of trace-level testing workflows, and we're already seeing an extraordinary amount of industry interest."
The Gallo pilot traces to a nearly decade-long Cornell-Gallo research collaboration that produced the underlying extraction geometry. "Curio is the product of nearly a decade of research partnership between Cornell University and E. & J. Gallo Winery," said Bruce Pan, Director of Chemistry, Research and Applications at E. & J. Gallo Winery. "That collaboration was instrumental in launching Quantera and continues to support the advancement and early application of Curio."
Bruker Corporation provides instrumentation and expertise in Quantera's laboratory. Quantera is a 2026 Grow-NY finalist and is implementing an ISO 9001 quality management system.
Early-access partners receive complimentary method development to migrate an existing headspace method to the platform. Upfront validation cost ranks as the most common adoption barrier, per sample prep automation survey data.
Does cartridge-based headspace analysis change what you can test?
Cartridge-based headspace analysis expands what a lab can test for because labs select the sorbent chemistry independently of the extraction hardware. Single-fiber workflows lock labs into coatings available for that fiber format, limiting the compound classes they can efficiently extract. The Curio HS separates sorbent choice from hardware; labs match cartridge chemistry to their target analytes across three broad categories:
- Aroma and flavor: Conventional polydimethylsiloxane (PDMS) and divinylbenzene (DVB) polymers for volatile organic compounds in food and beverage matrices
- Environmental: Novel advanced sorbents for challenging matrices including BTEX (benzene, toluene, ethylbenzene, and xylene) compounds in water and soil
- Budget-driven: Interchangeable cartridges let labs trade up or down in sorbent sophistication without changing the device or workflow

The Curio HS sealing press applies even pressure across all wells simultaneously, creating sealed headspace chambers in under two minutes per plate.
Quantera Analytical
The cartridge format enables field sampling that single-fiber extraction cannot match. A technician loads samples at the point of collection, whether in a vineyard, at a dairy intake dock, or at a brewery tank, then ships sealed cartridges to the lab rather than crates of raw material. Captured analytes hold stable on the cartridge during transit, eliminating cold-chain logistics and the throughput pressures food labs face when perishable samples arrive faster than instruments can run them.
The Curio HS runs on GC-MS and GC-FID by standard injection and DART-MS (direct analysis in real time mass spectrometry) by direct introduction, with liquid chromatography support under development for labs building toward GC-MS or LC-MS workflows. For surge-volume programs, including smoke taint screening during wildfire events, off-flavor investigation in a production tank, and pesticide residue screening at harvest, batching samples in parallel rather than queuing them behind a single extraction point changes what a lab can afford to test. Where the platform fits within a broader testing program depends on analyte priorities, instrument access, and quality assurance principles specific to each lab's production context.
Parallel headspace analysis: from spot check to production scale
The Curio HS combines parallel extraction, interchangeable sorbent cartridges, and compatibility with existing GC-MS and DART-MS instruments to address the throughput, cost, and logistics constraints that have kept headspace analysis a spot-check tool rather than a routine production control. Active co-validation with the USDA Agricultural Research Service, E. & J. Gallo Winery, and a major contract laboratory gives quality teams the third-party method evidence most require before committing to a new extraction platform. As chromatography-free mass spectrometry options mature and per-instrument costs fall, the combination of parallel extraction and flexible sorbent chemistry positions headspace analysis to reach compound classes and sample volumes that were previously impractical to test routinely.
This content includes text that has been generated with the assistance of AI. For more information, view Lab Manager's AI use policy.














