Scientists at Purdue University's Bindley Bioscience Center have developed surface touch extraction imaging (STEi), a patent-pending automated method that eliminates the multi-step sample preparation (sample prep) required for conventional liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. Using a pressure-controlled probe, STEi extracts metabolites, lipids, proteins, and environmental compounds from intact samples and generates spatially resolved chemical maps without cutting, grinding, or flattening the source material.
Editor's Note: Analysts running LC-MS workflows on biological tissues or food matrices routinely spend the first half of their day on sample prep (weighing, mixing, centrifuging, transferring, and drying aliquots) before acquiring a single data point. That labor falls on method development scientists to optimize and on lab managers to schedule around instrument downtime and throughput demands. Lab managers evaluating STEi should ask whether their current throughput losses during sample prep are quantifiable before their next capital planning cycle.
Why conventional LC-MS sample preparation destroys spatial data
Conventional LC-MS/MS sample preparation destroys the chemical location of every compound before analysis begins. The five standard steps (weighing, mixing, centrifuging, transferring, and drying) produce a homogenate that reveals which molecules were present, but not where they were concentrated in the original tissue or food matrix.
"That destroys the sample and throws away spatial information about where a chemical was found in the sample," said Christina Ferreira, research assistant professor at Purdue's Bindley Bioscience Center. "Also, if scientists want to spatially analyze an irregular surface such as a piece of liver tissue or a fish fillet, they must section it and make it flat to be able to extract the chemicals before the analysis."
Desorption electrospray ionization MS (DESI-MS) and matrix-assisted laser desorption ionization (MALDI) imaging, the two established spatial MS techniques, both require flat, sectioned surfaces, and most analytical labs lack the infrastructure to support them. STEi removes the sectioning requirement entirely, extracting surface chemistry from irregular, three-dimensional samples and eliminating the specialist skill dependency those methods carry. Labs reviewing recent mass spectrometry developments in spatial workflows will find this a meaningful reduction in within-run variability.
How does STEi replace LC-MS sample preparation?
STEi replaces conventional LC-MS sample preparation with a single operator step. The user loads an intact sample (tissue biopsy, food item, or packaging material) onto the instrument stage, and the system takes over: an integrated camera scans the surface, software maps a probe path, and a fine probe tip contacts each programmed point for 5–15 seconds, drawing compounds into a small volume of solvent (water, acetonitrile, or a mixture) through a liquid bridge. A force/pressure sensor maintains consistent contact across uneven topography without operator adjustment.
"The STEi concept workflow allows the user to load a sample, press 'Run' and create a spatially resolved chemical portrait of their sample based on an instrumentation input, without ever having to cut, grind or destroy it," Ferreira said. Coordinate data feeds back to the original surface map, producing heat maps that show where specific lipids, contaminants, proteins, or metabolites concentrate across the sample.
This automated mapping process fundamentally shifts how analytical teams handle irregular biological specimens. The Purdue team successfully demonstrated the recovery of approximately 2,000 distinct proteins from bovine muscle tissue using a manual version of STEi, showcasing broad utility. Key operational characteristics of the STEi method include:
- Surface sampling preserves the specimen for repeat measurements over time.
- Pressure-controlled contact manages irregular surfaces without manual recalibration.
- Coordinate-registered heat maps replace single-point average concentration data.
- System output routes directly to high-performance liquid chromatography autosamplers.
| Workflow dimension | Conventional LC-MS/MS sample prep | STEi |
|---|---|---|
| Sample state required | Homogenized, flat, or sectioned | Intact; irregular surfaces accepted |
| Steps before injection | 5 (weigh, mix, centrifuge, transfer, dry) | 1 (load sample, press Run) |
| Spatial data retained | None; spatial context destroyed | Full coordinate-registered heat map |
| Time to first extraction | 30+ minutes for most matrices | 5–15 seconds per surface point |
| Staff skill requirement | Sample prep method expertise | Standard instrument operation |
| Sample reuse | Not possible; sample consumed | Repeated sampling over time |
| Downstream instrument compatibility | LC-MS/MS after prep | HPLC autosampler or LC-MS/MS direct |
What applications does STEi target?
STEi targets food safety contaminant mapping, preclinical toxicology, and environmental residue detection by enabling repeated nondestructive sampling. In food safety, the method addresses a capability that destructive assays cannot match: repeated nondestructive sampling of fresh produce, poultry, dairy, and fish over time to track molecular spoilage without consuming the specimen. Labs working toward compliance with FDA food safety regulations should note that reducing specimen counts for contaminant mapping studies carries downstream implications for sampling plan documentation under 21 CFR Part 117 and the Food Safety Modernization Act (FSMA).
STEi can map the metabolic impact of drugs across liver, kidney, brain, and intestinal tissue from animal models, providing spatial drug distribution data that a homogenate-based workflow cannot recover. Lab managers overseeing preclinical studies will find STEi relevant to discussions about reducing manual steps in high-throughput lab workflows, where specimen consumption and prep time are primary cost drivers. The team is also pursuing regulatory alignment with both the FDA and the U.S. Environmental Protection Agency for environmental monitoring applications.
Evaluating surface touch extraction imaging for spatial MS procurement
Lab managers evaluating capital investment in spatial MS should benchmark their current LC-MS sample preparation costs (labor hours per run, specimens consumed per study, and throughput lost to multi-step prep) against what a probe-based approach eliminates. While STEi is not yet commercially available, the development pathway remains open for organizations ready to support validation testing.
Facilities with high-throughput spatial analysis requirements stand to recover the most baseline efficiency from early engagement. This applies particularly to laboratories where repeated sampling of the same specimen over time is currently impossible. Implementing such automated methods ultimately provides analytical teams with richer data sets and fewer manual intervention points.