Whole Genome Sequencing Cost Falls with Solaris 2.0 Max

Ultima Genomics doubles sequencing output and adds paired-end reads, reshaping the economics of large-scale germline and biobank programs

Written bySharon Dong
| 4 min read
A Black female genomics scientist examines paired-end sequencing run data on a wall monitor inside a high-throughput NGS core facility.
Register for free to listen to this article
Listen with Speechify
0:00
4:00

A new whole genome sequencing cost milestone emerged at the American Society of Human Genetics (ASHG) 2026 Annual Meeting. Ultima Genomics announced the commercial launch of paired-end sequencing on its UG200 Series and the availability of Solaris 2.0 Max sequencing consumables, which deliver up to 20 billion reads per wafer and bring the per-genome price to $60 at 30x coverage on the UG200 Ultra.

Editor's Note: The $60 genome price point, combined with paired-end read compatibility, addresses two longstanding barriers to NGS deployment at scale: reagent costs that made large cohorts difficult to justify, and single-end chemistry limitations that constrained adoption in clinical germline pipelines. Genomics core managers and PI teams building biobank or population-scale workflows should assess whether the Solaris 2.0 Max output tiers (5, 10, and 20 billion reads per wafer, with the lower configurations arriving in early 2027) match their project size and instrument fleet.

How whole genome sequencing cost has changed

Whole genome sequencing cost has declined by six orders of magnitude since systematic tracking began. NHGRI cost data places the per-genome figure at approximately $95 million in September 2001; next-generation sequencing (NGS) platforms began displacing Sanger-based methods in 2008 and drove it to roughly $1,000 by approximately 2014. Ultima Genomics reached the $100 level in 2022, and Solaris 2.0 Max now brings whole genome sequencing cost to $60 per 30x genome on the UG200 Ultra, a 40% reduction.

Per-wafer output doubles alongside the price reduction. The UG200 Ultra running Solaris 2.0 Max sequences up to 60,000 30x whole human genomes per year, compared to approximately 30,000 on the same platform with Solaris 2.0. Labs evaluating whether high-throughput sequencing is sustainable for large cohorts now have a concrete cost-per-sample figure to model against their budget.

What does paired-end sequencing add to germline workflows?

Paired-end sequencing reads both ends of each DNA fragment, improving read mapping in regions where single-end chemistry falls short. For germline whole genome sequencing (WGS), the gain is most meaningful in three problem areas labs have had to work around on single-end platforms:

  • Homopolymer tracts: Repeated single-nucleotide runs that single-end reads struggle to map accurately, leading to false-positive variant calls in affected regions.
  • Segmental duplications: Near-identical genomic segments where fragment-end anchoring from both sides allows the aligner to disambiguate copy number and origin.
  • Structural variant boundaries: Insertions, deletions, and inversions that require reads spanning both sides of the breakpoint for reliable detection.

Paired-end mode on the UG200 Series runs approximately 13.4 hours per wafer, compared to the 6.0–11.2 hour range for single-end runs. The UG200 Ultra produces 24 wafers per week in paired-end mode versus up to 60 in single-end mode, a real throughput trade-off labs should factor into run scheduling. Both read modes are available on the same instrument, so labs do not need separate capital infrastructure for each workflow type.

Lab manager academy logo

Advanced Lab Management Certificate

The Advanced Lab Management certificate is more than training—it’s a professional advantage.

Gain critical skills and IACET-approved CEUs that make a measurable difference.

Paired-end reads also strengthen Ultima's in-development pangenome-aware analysis pipeline, built with NVIDIA using Google's open-source DeepVariant. Ultima and NVIDIA are benchmarking this graph-based approach against traditional linear-reference pipelines using Human Pangenome Reference Consortium (HPRC) resources, with NVIDIA Parabricks supplying GPU-accelerated Giraffe and DeepVariant. Labs examining how pipeline design shapes variant-calling accuracy at population scale will find this collaboration a practical reference for pangenome workflow planning.

Solaris 2.0 Max doubles output and adds paired-end capability

For labs deciding between the two consumable versions, the differences in cost, throughput, and read-mode support on the UG200 Ultra are the most operationally relevant factors.

SpecificationSolaris 2.0Solaris 2.0 Max
Reads per waferUp to 10 billionUp to 20 billion
30x WGS cost per genome (UG200 Ultra)~$100~$60
Annual 30x WGS genomes (UG200 Ultra)~30,000Up to 60,000
Paired-end supportNoYes
Available read configurations10B reads/wafer20B now; 5B and 10B in early 2027
Platform compatibilityUG200 Series, UG100UG200 Series, UG100

Clinical and functional genomics: what early users found

Paired-end sequencing and Solaris 2.0 Max were deployed at several customer sites through an early access program, generating feedback across two distinct workflow contexts. David Schlesinger, CEO and co-founder of Mendelics, evaluated the chemistry for clinical germline applications, a setting where read quality in complex genomic regions directly affects diagnostic precision in rare disease programs.

"We are a large clinical laboratory focused on delivering the highest quality testing on the most advanced technologies to patients," said David Schlesinger. "We have been evaluating Ultima's paired-end sequencing capability for clinical germline applications. The technology represents a significant advance in quality over previous generations of Ultima chemistry, and we have identified many areas of the genome where this capability offers marked improvements over other approaches."

Want to stay up to date on the latest lab management news?

Register for a FREE Lab Manager account to subscribe to our Lab Manager Monitor Newsletter.
Subscribe for Free

Ajamete Kaykas, Chief eXploration Officer at Insitro, ran one of the organization's largest Perturb-seq experiments on the platform, generating hundreds of billions of reads in days on a small number of instruments. At that scale, iterative large-screen design becomes economically viable for functional genomics programs where high-volume runs repeat by design.

"Generating data at this scale quickly and affordably lets us routinely run large screens and refine each experiment, exactly what it takes to build foundational datasets," said Ajamete Kaykas.

"Paired-end sequencing and Solaris 2.0 Max are the two capabilities our customers have asked for most as they work to deploy Ultima's sequencing technology across more applications, especially germline applications requiring clinical quality," said Gilad Almogy, founder and CEO of Ultima Genomics. "Doubling output while bringing the genome to $60 changes what is economically possible for large programs, health systems, and biobanks — and with paired-end reads and pangenome-aware analysis, they can get ultra-high throughput, low cost, and quality in the same sequencing runs."

The Precure initiative, a joint venture between Mayo Clinic and Thermo Fisher Scientific, selected the UG200 Ultra to generate WGS data from one million multi-omic biospecimens. Helix, Inc. operates as the multi-omics lab, integrating WGS with proteomic and longitudinal clinical data to support AI/ML-driven discovery.

Evaluating Solaris 2.0 Max for high-throughput WGS programs

The Solaris 2.0 Max launch combines two capabilities that have historically required separate trade-offs in high-throughput WGS: lower whole genome sequencing cost per sample and the read-pair data quality needed for germline and pangenome workflows. Labs with large-scale WGS or functional genomics programs should request Ultima's Solaris 2.0 Max application notes and compare the 20 billion read-per-wafer configuration against their current cohort size and run frequency before committing to a reagent procurement timeline. The 5 and 10 billion read configurations arrive in early 2027, giving labs with smaller programs a lower-output entry point into the same chemistry.


This content includes text that has been generated with the assistance of AI. For more information, view Lab Manager's AI use policy.

Add Lab Manager as a preferred source on Google

Add Lab Manager as a preferred Google source to see more of our trusted coverage.

About the Author

  • asian woman in a malaysian-chinese batik shirt with glasses, smiling

    Sharon Dong, MSc, BSc (Hons), joined LabX Media Group (LMG) in 2026 as a Product News & Intelligence Editor. She has a strong background in cellular biology, microbiology, immunology, and molecular genetics. She is an experienced science education and outreach facilitator. Sharon is passionate about communicating science in ways that are clear, engaging, and accessible to a broad audience. In her free time, she enjoys solving jigsaw puzzles and cooking. Sharon can be reached at sdong@labxmediagroup.com.

    View Full Profile

Related Topics

Loading Next Article...
Loading Next Article...
Current Magazine Issue Background Image

CURRENT ISSUE - October 2026

Why Lab Teams Resist Change—And How Leaders Can Respond

Addressing the human side of automation, AI, and operational change

October 2026 Lab Manager Cover Image