Ensuring Sample Validity: A Comprehensive Guide to Field-to-Lab Chain-of-Custody

Robust field-to-lab protocols are fundamental to sample integrity, minimizing legal risk, and maintaining the highest standards of quality in environmental lab operations.

Written byCraig Bradley
| 6 min read
Register for free to listen to this article
Listen with Speechify
0:00
6:00

The integrity of analytical results hinges entirely on the field-to-lab chain-of-custody (COC) process, a critical administrative and physical procedure that tracks samples from the point of collection until final disposal. For environmental labs and various other testing facilities, establishing an unbroken COC is non-negotiable, providing the legally defensible proof that a sample analyzed is precisely the sample collected and that its characteristics have not been compromised. Sound lab operations rely on stringent adherence to these protocols to guarantee that any data generated accurately represents the original material. The COC documentation serves as a chronological record, establishing proof of possession and transfer of every sample, thereby upholding the validity of all analytical findings.

Establishing critical steps in initial field-to-lab documentation and preparation

Initial documentation and preparation steps define the quality and defensibility of the entire field-to-lab COC. This phase establishes the first link in the legal evidence trail, making precision mandatory for personnel operating in the field. Before any material is collected, the appropriate containers, preservatives, and labeling systems must be verified against established methods and regulatory requirements. Failure to use the correct preservative or container type can immediately invalidate the sample for its intended analysis, irrespective of subsequent laboratory handling.

Once the sample is collected, standardized procedures for identification must be employed. Every sample container receives a unique, non-reusable identifier, typically affixed with an indelible, water-resistant label. This label must clearly communicate essential information, including the sample identification number, the date and time of collection, the sampler’s initials, the location of collection (GPS coordinates or specific site name), and any preservation method used. This detailed record is the foundation of the COC form itself.

The initial COC form, which begins in the field, serves as the master record. It includes a comprehensive list of all collected samples, the specific analyses requested for each, and the requested holding times. The field technician initiating the form must sign and date it, signifying transfer of custody, typically to a transport or courier representative. This transfer must be recorded with a corresponding signature and date on the form, marking the explicit exchange of responsibility. The use of tamper-evident seals immediately after collection and before the initial transfer provides a physical assurance that sample integrity remains intact during the field-to-lab transit phase.

Essential field documentation components:

  • Unique sample ID and container volume.
  • Date, time, and specific location (including coordinates if necessary).
  • Name and signature of the sampler.
  • Preservative used (e.g., pH adjustment, refrigeration).
  • Requested analyses/methodology.
  • Initials and date for every custody transfer.

Maintaining sample integrity through preservation and transport protocols

The period between collection and receipt at the laboratory is the most vulnerable phase for sample integrity, making meticulous preservation and transport protocols essential to the COC. Sample characteristics can rapidly change due to physical, chemical, or biological processes, which necessitates immediate and appropriate preservation. This step is critical, particularly for volatile organic compounds, trace metals, and biological indicators, which often require specific temperature control or chemical fixation.

Temperature control is paramount, as maintaining samples at a defined temperature 4 degrees Celsius (+/- 2 degrees) for many environmental parameters) slows down biological and chemical degradation. Samples must be immediately placed in coolers with ice or ice packs, and temperature blanks should be included to monitor the cooling process continuously. The temperature upon receipt at the laboratory is a crucial quality check; samples arriving outside the acceptable range compromise the defensibility of the subsequent analytical data.

Furthermore, transport must ensure physical protection against breakage or cross-contamination. Secure packaging, adequate cushioning, and separation of highly contaminated or volatile samples from others are required to prevent matrix interference. The elapsed time from collection to analysis must strictly adhere to regulatory holding times. Exceeding these maximum time limits, as stipulated by required methods (such as those governed by the U.S. Environmental Protection Agency under 40 CFR Part 136 for water samples or EPA SW-846, Test Methods for Evaluating Solid Waste for waste matrices, key references for environmental labs), renders the analytical data non-compliant and often unusable for regulatory purposes. The unbroken line of transport, documented at every handoff on the COC form, verifies that the sample was never unattended and arrived at the facility ready for analysis.

Lab manager academy logo

Lab Quality Management Certificate

The Lab Quality Management certificate is more than training—it’s a professional advantage.

Gain critical skills and IACET-approved CEUs that make a measurable difference.

Auditable COC procedures for regulatory compliance

The strength of the field-to-lab COC lies in its absolute auditability and ability to withstand legal scrutiny. The physical COC form is the backbone of this system, requiring meticulous completion at every stage of the sample’s lifecycle. Each individual who takes possession of the sample, even briefly, must sign the form, recording the date, time, and purpose of the transfer. This sequence of signatures provides an unbroken, chronological record of custody, proving that control was never lost.

For lab operations seeking accreditation, such as under ISO/IEC 17025 standards, stringent control over COC documentation is regularly audited. The procedures must define who can access the samples, how they are stored (e.g., locked refrigerators or restricted-access sample receipt areas), and the process for transfer internally to the analytical bench. Any internal transfer—for example, from the sample receiving department to the preparation bench, and subsequently to the analytical instrument—must be documented, often via internal laboratory COC forms or LIMS (Laboratory Information Management System) entries, which are cross-referenced with the original field COC.

Stage of custody

Responsible party

Documentation requirement

Integrity check

Field collection

Field technician

Unique ID, date/time, location, preservative

Tamper seal applied

Transport

Courier/carrier

Signature and time of transfer (out and in)

Cooler temperature logged

Lab receipt

Sample custodian

Signature, time of receipt, condition of sample

Seal integrity, temperature check

Internal processing

Analyst/prep tech

Internal LIMS/COC, subsample weight/volume

Hold time verification

Maintaining multiple copies of the COC form (typically a multi-part carbon copy system) ensures that both the field crew and the laboratory retain a signed copy of the final transaction. This redundancy is essential for reconciliation and dispute resolution.

Interested in lab leadership?

Subscribe to our free Lab Leadership Digest Newsletter.

Is the form not loading? If you use an ad blocker or browser privacy features, try turning them off and refresh the page.

By subscribing, you agree to receive email related to Lab Manager content and products. You may unsubscribe at any time.

Seamless COC integration within environmental lab operations

The final stages of the field-to-lab COC occur entirely within the laboratory environment, where the sample is formally integrated into the quality management system. The Sample Custodian is typically the first point of contact, responsible for sample receipt and logging. This process involves a detailed reconciliation where the custodian verifies the physical samples against the submitted COC form, checking for discrepancies such as broken seals, missing containers, insufficient volume, or damaged labels.

Upon successful inspection, the samples are formally accepted, and the final signature is applied to the field COC form, closing the chain of physical transfer from the field team. The data is then entered into the LIMS, which automatically assigns a unique laboratory ID (or cross-references the field ID) and tracks its progress through all subsequent analytical steps. The LIMS becomes the digital extension of the COC, documenting aliquots taken, the instrument used, the analyst responsible, and the date and time of analysis.

Proper management of laboratory inventory and storage is the last physical aspect of the COC. Samples must be stored under secure, controlled conditions until analysis is complete, data is reviewed, and the regulatory retention period has expired. This secure storage ensures that if re-analysis is required, the sample available remains defensible. Final disposition, whether by controlled waste disposal or return to the client, must also be documented in the LIMS. Stringent adherence to these protocols strengthens overall lab operations, minimizing errors and maximizing the certainty of every result.

Reinforcing data defensibility through strict field-to-lab COC protocols

Strict adherence to field-to-lab COC protocols is not merely a procedural requirement; it is the cornerstone of analytical quality and data defensibility. By meticulously tracking possession and condition, laboratories demonstrate competence, maintain accreditation, and ensure that their analytical findings are legally and scientifically sound, protecting both the client and the laboratory from liability. This system is foundational to reliable environmental lab data.


Frequently asked questions about chain-of-custody

What is the primary purpose of field-to-lab chain-of-custody documentation?

The primary purpose of field-to-lab chain-of-custody documentation is to provide a legally defensible, unbroken record of the sample's possession and handling. This documentation proves that the sample analyzed by the environmental labs is the same material collected in the field, assuring that no tampering or unauthorized substitutions have occurred.

How does temperature control impact the chain-of-custody process?

Temperature control is a critical aspect of the field-to-lab process, as it is a measure of sample integrity. Maintaining specific temperatures (often $4^\circ\text{C}$) during transport is essential to slow down chemical and biological degradation. If a sample arrives at the lab outside the acceptable temperature range, the integrity of the sample is compromised, and the data generated from its analysis may be rendered invalid, thereby breaking the scientific continuity of the chain-of-custody.

What role does LIMS play in chain-of-custody within lab operations?

A Laboratory Information Management System (LIMS) acts as the digital extension of the physical chain-of-custody form once the sample is accepted into lab operations. The LIMS tracks the sample's internal life cycle—including sub-sampling, aliquot preparation, analysis assignment, analyst name, and disposal—creating an auditable digital trail that links the final report back to the original field documentation.

This article was created with the assistance of Generative AI and has undergone editorial review before publishing.

About the Author

  • Person with beard in sweater against blank background.

    Craig Bradley BSc (Hons), MSc, has a strong academic background in human biology, cardiovascular sciences, and biomedical engineering. Since 2025, he has been working with LabX Media Group as a SEO Editor. Craig can be reached at cbradley@labx.com.

    View Full Profile

Related Topics

Loading Next Article...
Loading Next Article...

CURRENT ISSUE - November/December 2025

AI & Automation

Preparing Your Lab for the Next Stage

Lab Manager Nov/Dec 2025 Cover Image